Netgear GS724T

  • CLI
    telnet 172.16.0.X 60000
    admin
    [Passwort]
    enable
    [Enter = Passwort ist leer]
    
    • VLANs einrichten
         vlan database
         vlan 999
         vlan name 999 ciscoIntern
      
         vlan 4
         vlan name 4 orange
      
         vlan 7
         vlan name 7 gruenKGy
      
         vlan 11
         vlan name 11 gruenKHWRS
      
         vlan 16
         vlan name 16 Unifi
      
         vlan 62
         vlan name 62 grauKGy
      
      
    • VLAN den Ports zuweisen
      • tagged oder untagged
        configure
        interface 3/1
        
        vlan tagging [VLAN#]
        no vlan tagging [VLAN#]
        
        vlan participation include [VLAN#] 
        
  • IPAdresse ändern
    • WebInterface (System-Management-IPConfiguration)
    • NetGear-Windows-Software (NIC muss am Switch hängen, VM-NIC muss bridged sein, dann erkennt die Software den Switch an der MAC)
  • Änderung auch in CLI möglich
  • VLAN's einrichten
  • LAG (LanAggregation)
    • LAG-Type LACP
    • VLANs auf LAG-Port untagged
  • Port in VLAN
    • VLAN Membership tagged festlegen
    • PVID (preferred VLAN) angeben
  • Port als Trunk
    • VLAN Membership aller VLAN untagged festlegen
    • PVID (preferred VLAN) angeben
  • Administratives Management VLAN 999
    erst zum Schluss setzen, sonst: Ausperrung!